linux系统下cpu温度查看方法

1.先确定你系统是不是64位
uname -p
x86_64
如果是x84_64,那么恭喜你,你可以继续看下去了,如果是i686和i386的,那不好意思,请你去重装系统吧.

2.安装
yum install lm_sensors -y

#配置
sh -c "yes|sensors-detect"

#加载模块
modprobe i2c-dev
modprobe coretemp (如果是64位系统,这步就直接通过了,如果是32位系统,这步是我弄死都过不去的一道坎)

#查看CPU温度

1、使用命令sensors (管理员用户,主节点)
[root@console ~]# sensors
w83627hf-isa-0a00
Adapter: ISA adapter
VCore 1:   +1.15 V  (min =  +0.00 V, max =  +0.00 V)       ALARM 
VCore 2:   +1.15 V  (min =  +0.00 V, max =  +0.00 V)       ALARM 
+3.3V:     +3.22 V  (min =  +3.14 V, max =  +3.47 V)             
+5V:       +5.11 V  (min =  +4.76 V, max =  +5.24 V)             
+12V:      +5.78 V  (min = +10.82 V, max = +13.19 V)       ALARM 
-12V:      -5.45 V  (min = -13.18 V, max = -10.80 V)       ALARM 
-5V:       +2.94 V  (min =  -5.25 V, max =  -4.75 V)       ALARM 
V5SB:      +5.67 V  (min =  +4.76 V, max =  +5.24 V)       ALARM 
VBat:      +3.34 V  (min =  +2.40 V, max =  +3.60 V)             
fan1:     5273 RPM  (min =    0 RPM, div = 8)                    
fan2:     5818 RPM  (min =    0 RPM, div = 8)                    
fan3:     5818 RPM  (min =  883 RPM, div = 8)                    
temp1:       +64°C  (high =    -1°C, hyst =    -1°C)   sensor = thermistor   ALARM  
temp2:      -3.0°C  (high =   +80°C, hyst =   +75°C)   sensor = diode          
temp3:      -3.0°C  (high =   +80°C, hyst =   +75°C)   sensor = diode          
vid:      +0.000 V  (VRM Version 8.2)
alarms:   Chassis intrusion detection                      ALARM
beep_enable:
          Sound alarm enabled
 
2、gpu
GPU 0000:82:00.0
    Product Name                : GeForce GTX 460
    Display Mode                : N/A
    Persistence Mode            : Disabled
    Driver Model
        Current                 : N/A
        Pending                 : N/A
    Serial Number               : N/A
    GPU UUID                    : N/A
    VBIOS Version               : 70.04.13.00.00
    Inforom Version
        OEM Object              : N/A
        ECC Object              : N/A
        Power Management Object : N/A
    PCI
        Bus                     : 0x82
        Device                  : 0x00
        Domain                  : 0x0000
        Device Id               : 0x0E2210DE
        Bus Id                  : 0000:82:00.0
        Sub System Id           : 0x23221462
        GPU Link Info
            PCIe Generation
                Max             : 2
                Current         : 1
            Link Width
                Max             : 16x
                Current         : 16x
    Fan Speed                   : 52 %
    Performance State           : N/A
    Memory Usage
        Total                   : 1023 MB
        Used                    : 3 MB
        Free                    : 1019 MB
    Compute Mode                : Default
    Utilization
        Gpu                     : N/A
        Memory                  : N/A
    Ecc Mode
        Current                 : N/A
        Pending                 : N/A
    ECC Errors
        Volatile
            Single Bit
                Device Memory   : N/A
                Register File   : N/A
                L1 Cache        : N/A
                L2 Cache        : N/A
                Total           : N/A
            Double Bit
                Device Memory   : N/A
                Register File   : N/A
                L1 Cache        : N/A
                L2 Cache        : N/A
                Total           : N/A
        Aggregate
            Single Bit
                Device Memory   : N/A
                Register File   : N/A
                L1 Cache        : N/A
                L2 Cache        : N/A
                Total           : N/A
            Double Bit
                Device Memory   : N/A
                Register File   : N/A
                L1 Cache        : N/A
                L2 Cache        : N/A
                Total           : N/A
    Temperature
        Gpu                     : 41 C
    Power Readings
        Power Management        : N/A
        Power Draw              : N/A
        Power Limit             : N/A
    Clocks
        Graphics                : N/A
        SM                      : N/A
        Memory                  : N/A
    Max Clocks
        Graphics                : N/A
        SM                      : N/A
        Memory                  : N/A
    Compute Processes           : Not Supported
可以看到我cpu的温度有点高,笔记本将就了.

ps:
其他查看cpu温度命令:
cat /proc/acpi/thermal_zone/THRM/temperature (这条我在我机器上是可以用的)

这两条没有测试过:

cat /sys/bus/acpi/devices/LNXTHERM\:00/thermal_zone/temp
cat /proc/acpi/thermal_zone/THM0/temperature

补充一篇文章:

监控cpu温度?显卡温度和硬盘温度

1.安装applet

luther@gliethttp:~$ apt-get install lm-sensors sensors-applet // 之后添加"Hardware Sensors Monitor到面板上,如果没有该applet,那么重启一下电脑就可以了.
luther@gliethttp:~$ sudo sensors-detect // 一路回车就可以了
效果图:

2.安装硬件检测软件

luther@gliethttp:~$ sudo apt-get install hddtemp
luther@gliethttp:~$ sudo hddtemp /dev/sda
/dev/sda: ST3160815AS: 36°C

时间: 2024-10-27 05:13:58

linux系统下cpu温度查看方法的相关文章

Linux系统下Telnet的设置方法

  Linux系统下Telnet的设置方法 Linux系统下Telnet服务的配置步骤: 一.安装Telnet软件包(通常要两个) 1. Telnet-clIEnt (或 Telnet),这个软件包提供的是 Telnet 客户端程序; 2. Telnet-server ,这个软件包提供的是 Telnet 服务器端程序; 安装之前先检测是否这些软件包已安装,方法如下: [root@echo root]#rpm –q Telnet或[root@wljs root]#rpm –q Telnet-cli

关于网络抓包,linux系统下kismet的使用方法

问题描述 关于网络抓包,linux系统下kismet的使用方法 我想知道k?i?smet怎么用呢?我看到它抓的包了,但怎么保存成文件?只看到它扫描到附近的Wi-Fi,能抓到客户端的包么? 解决方案 使用XILINX SDK工具通过网络进行基于linux系统的远程调试方法Linux下抓包工具tcpdump使用方法Linux下的网络HOOK实现以及使用方法

Linux系统下fd分配的方法

最近几天在公司里写网络通讯的代码比较多,自然就会涉及到IO事件监测方法的问题.我惊奇的发现select轮训的方法在那里居然还大行其道.我告诉他们现在无论在Linux系统下,还是windows系统下,select都应该被废弃不用了,其原因是在两个平台上select的系统调用都有一个可以说是致命的坑. 在windows上面单个fd_set中容纳的socket handle个数不能超过FD_SETSIZE(在win32 winsock2.h里其定义为64,以VS2010版本为准),并且fd_set结构

Linux系统下软件包的制作方法和过程

  总的情况下Linux下软件安装主要有三种方式: 一种是源码安装,需要用户自己手动编译 另一种是RPM包(RedHat Linux Packet Manager),通过RPM命令就可以实现安装 还有一种为*.bin文件,安装方法与Windows下的安装过程类似 通常情况下Linux 安装软件主要通过以下两种方式 ① 文件名形如xxx.i386.rpm ,软件包以二进制形式发布. ② 文件名形如xxx.tar.gz ,软件包多以源码的形式发布. Linux软件包管理可以分为三类:二进制包的管理,

Win7 64位旗舰版系统下CPU温度过高的解决方案

  一般情况下CPU的温度在80度左右是为正常温度,如果是90-100的话,这温度就太高了,有时候估计CPU本身就会出现硬件问题,具体方法如下: 1.在机箱上面加一个辅助的外置风扇,或者买一个小风扇对准机箱,加快机箱内部的散热; 2.首先对电脑机箱做一下简单的维护,可以清理一下机箱内部的灰尘,尤其是CPU,以及风扇附件的灰尘都要细心清理,然后对CPU重新涂抹硅胶防止cpu过热; 3.给CPU的散热风扇加点润滑油,提高散热风扇的性能,如果觉得散热风扇风力不够强的话,建议大家可以更换一个新的散热能力

Linux系统下ADSL拨号上网方法

本指南将帮助你在Ubuntu 6.06 LTS (Dapper Drake)下用PPPoE以太网modem建立ADSL网络连接. 1. 简介 虽然用路由器联网很常见,我们有时也需要用PPPoE直接连接到ADSL(有时也叫DSL) modem. 当然首先你要付好钱给网通或电信什么的 网络运营商,把线路接好.modem上的"DSL"灯亮,一般表示你的线路通畅. 你要有账号的用户名和密码.Modem和以太网卡之间还得用合适的网络线连接起来. 2. 用命令行配置PPPoE 设置modem要用终

linux系统下sudo命令使用方法详解

介绍 sudo是linux系统管理指令,是允许系统管理员让普通用户执行一些或者全部的root命令的一个工具,如halt,reboot,su等等.这样不仅减少了root用户的登录和管理的时间,同样也提高了安全性.sudo不是对shell的一个代替,它是面向每个命令的. sudo命令 sudo -K -L -V -h -k -l -vsudo [-HPSb] [-a auth_type] [-c class-] [-p prompt] [-u username#uid] {-e file [...]

SuSE Linux系统下设定Apache的方法

Apache需要设定成虚拟网站空间方式. 新版SuSE的Apache已经改成模组化. 所以只要修改几个档案就可以在建立帐号时,网站就对应的到位置. 而不用去修改http.conf一个个建对应/home的位置,建完还要重新启动Apache . 1.修改/etc/sysconfig/apache2 ]#vi /etc/sysconfig/apache2 找APACHE_MODULES 在最后面加上vhost_alias 存档重新编译apach2的设定档让apache2载入vhost模组 ]#SuSE

Linux系统下安装Memcache的方法

1.分别把memcached和libevent下载回来,放到 /tmp 目录下: # cd /tmp # wget http://www.danga.com/memcached/dist/memcached-1.2.0.tar.gz # wget http://www.monkey.org/~provos/libevent-1.2.tar.gz 2.先安装libevent: # tar zxvf libevent-1.2.tar.gz # cd libevent-1.2 # ./configur